opens in new tab or window
Skip to main content
Quick Links
Facebook
Instagram
English (United States)
Select this as your preferred language
Select a language to translate to
English (United States)
Select this as your preferred language
Open
Search
Menu
Residents
Information for Residents
New Resident Guide
Who to call when you need help
Permit Center
Prepare Our Island
Airport Noise
Estuary Bridges
Alameda CARE Team
Be Alameda Ready
Subscribe
Get Around Alameda
City Tobacco Ordinances
Alerts & Advisories
Alameda 4th of July Parade
Auto Parking in Alameda
Park and Webster Street Area Parking
Parking Citations and Enforcement
Auto Parking FAQs
Ferry Terminal & Transit Parking
Curb Management Policy and Planning
Island Hopper: Alameda Point's Free Weekend Shuttle
City of Alameda Guaranteed Income Pilot Program
Making Alameda Accessible (ADA)
Visit Alameda
Events
Attractions
Travel Around Alameda
New Resident Guide
Accommodations
July 4th Parade - Classic & Convertible Cars & Drivers Needed!
Business
Starting a Business in Alameda
Business Licensing & Permits
Programs and Information
Local Campaigns 2025
Facade Grant Program
At Your Service
Business News from the Island
Market Information
Business Associations & Improvement Areas
Leasing City-Owned Properties
Employment Resources
Resources for Employers
Resources For Job-Seekers
Business Registration for 10th Annual Job Fair
Bid on City Contracts
Notice of Funding Availability & Request for Proposals
Request for Proposals for Cultural Art and Arts Programming
Pavement Management Project Phase 42
Invitation to Bid Alameda Point Building 116 Demolition Project
RFP On Call Residential Roof Repair, Maintenance, and Replacement
RFP On Call Fire Alarm Inspection and Monitoring Services
RFP On Call Maintenance and Inspection Services for Fire Sprinkler Sys
RFP Alameda Point Security Patrol
Alameda Point Building 17 Board Up Project BRED No. 2025-07
Request for Proposal: Grand Marina Wharf Maintenance
Request for Proposal: Commercial Real Estate Broker(s)
Alameda Day Center Project HHS No. 25-01
2026 Residential Property Management RFP
RFP For Waste & Hazardous Waste Removal & Disposal Services
HOME Investment Partnership Program Housing Development RFP
Residential Rehabilitation Program Administrator RFP
Geographic Information System (GIS)
City of Alameda Citywide Viewer
Your Government
Elected Officials
Mayor Marilyn Ezzy Ashcraft
Vice Mayor Michele Pryor
Councilmember Tony Daysog
Councilmember Greg Boller
Councilmember Tracy Jensen
City Auditor, Kevin R. Kearney, CPA
City Treasurer, Kevin Kennedy
City Council Priorities
City Departments
Strategic Plan
Key Documents
Boards & Commissions
Applications, Appointments and Vacancies
Civil Service Board
Commission on Persons With Disabilities
Historical Advisory Board
Housing Authority Board of Commissioners
Planning Board
Public Art Commission
Online Application: Boards/Commissions
Meeting Agendas, Minutes & Videos
City News
Sister Cities
Coast Guard City
Public Comment and City Council Meeting Information
State of the City
Alameda In The News
Proclamations 2026
CITYWIDE PROJECTS
Programs and Services Addressing Homelessness
Warming Shelter
Homelessness Strategic Plan
Point-In-Time Count
Traffic Safety and Transportation
Heritage Months
Converting City Halls to drought-tolerant landscape
City Aquatic Center
De-Pave Park
Making Alameda Accessible (ADA)
Zero Waste Implementation Plan Update
Stronger Together
Search
HOME
/
Planning • Building • Transportation
/
Permit Center
/
Smoke & CO Alarms Residential Requirements
Smoke & CO Alarms Residential Requirements
CODE SECTION
CRC 314 & 315
SMOKE ALARMS
WHERE REQUIRED
In each sleeping room.
Outside each separate sleeping area in the immediate vicinity of the bedrooms.
On each story of the dwelling, including basements and habitable attics, not including crawl spaces and uninhabitable attics. In units with split levels and without an intervening door between adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.
SPECIFIC LOCATION REQUIREMENTS
Alarms shall be > 3’ from the opening of a shower room, if possible.
Alarms shall be > 20’ from cooking appliances, if possible.
Exceptions:
Ionization alarms with an alarm-silencing switch or photoelectric alarms shall be permitted to be installed 10’ from a cooking appliance.
Photoelectric alarms shall be permitted to be installed 6’ from a cooking appliance where the kitchen or cooking area and adjacent spaces have no clear interior partitions and the 10’ distances would prohibit the placement of a smoke alarm or smoke detector required by other sections of the code.
Smoke alarms listed for use in close proximity to a permanently installed cooking appliance.
Alarms shall be > 36” from the heating/cooling registers & ceiling fans
For stairways leading up from a basement, smoke alarms shall be located on the basement ceiling near the entry to the stairs.
For tray ceilings, alarms shall be installed on highest portion of the ceiling or on the sloped portion of the ceiling within 12” vertically down from the highest point.
INTERCONNECTION
Where more than one alarm is required to be installed within a unit, the alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the unit.
Exception:
Interconnection is not required in areas that are not undergoing alterations, repairs or construction.
POWER SOURCE
Alarms shall receive their primary power from the building wiring and be equipped with a battery backup.
Exceptions:
Alarms are permitted to be solely battery operated in existing buildings where no construction is taking place.
Alarms are permitted to be solely battery operated in existing areas of buildings undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure.
CARBON MONOXIDE (CO) ALARMS
WHERE REQUIRED
For existing buildings and new construction, CO alarms shall be provided where
either or both
of the following conditions exist.
The unit contains a fuel-fired appliance or fireplace.
The unit has an attached garage with an opening that communicates with the unit.
ALTERATIONS, REPAIRS AND ADDITIONS
Where an addition is made to an existing dwelling, or a fuel-burning appliance or fireplace is added to an existing dwelling, not previously required to be provided with carbon monoxide alarms, new CO alarms shall be installed.
Exceptions:
Work involving the exterior surfaces of dwellings.
Installation, alteration or repairs of plumbing or mechanical systems.
LOCATION
Outside of each separate sleeping area in the immediate vicinity of the bedrooms.
On every occupiable level of a dwelling unit, including basements.
Where a fuel-burning appliance is located within a bedroom or its attached bathroom, a CO alarm shall be installed within the bedroom.
INTERCONNECTIVITY
Where more than one CO alarm is required to be installed within a dwelling unit, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the dwelling unit.
POWER SOURCE
CO alarms shall receive their primary power from the building wiring and shall be equipped with a battery backup.
Exceptions:
CO alarms are permitted to be solely battery operated in existing buildings where no construction is taking place.
CO alarms are permitted to be solely battery operated in existing areas of buildings undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure.
CO alarms are permitted to be solely battery operated where repairs or alterations are limited to the exterior surfaces of dwellings
Revised: April 1, 2023